Á¦Ê¿ÀÖDKC01.1-040-7-FWËÅ·þÇý¶¯Æ÷Í£Ö¹ÔËÐÐC220¹ÊÕÏάÐÞ

·¢²¼ÕߣºHP    À´Ô´£ºÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾     ·¢²¼Ê±¼ä£º2022-10-9

Á¦Ê¿ÀÖDKC01.1-040-7-FWËÅ·þÇý¶¯Æ÷Í£Ö¹ÔËÐÐC220¹ÊÕÏάÐÞ

Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷άÐÞ¹«Ë¾£º¸Õ¸ÕÍê³ÉÁËΪÆÚËÄÌìµÄ¹ÊÕÏÅųý¹¤×÷£¬Éæ¼°²©Ê¿Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷¡£ÔÚÏßÐÔ¶¨³¤Ó¦ÓÃÖУ¬¿Í»§ÌåÑéÁËËÅ·þµç»úµÄ²»Îȶ¨ÐÐΪ¡£ËÅ·þÇý¶¯Æ÷λÓÚľ´°ÖÆÔ쳧µÄ´óÐͼӹ¤ºÍ×°ÅäÏßµÄÄ©¶ËÉèÊ©¡£µ±ÎÒµ½´ï¹¤³§Ê±£¬Ê×ÒªÈվͻ¨Á˺ܶàʱ¼äÀ´ÊìϤ¸Ãϵͳ£¬ÒòΪËüÊÇÒ»¸ö·Ç³£¸´ÔÓµÄÉèÖ㬲¿·Ö¿Ø¼þÔÚ¹ý³ÌÖб¾µØ±à³Ì£¬²¿·Ö¿Ø¼þÀ´×ÔÖ÷PCµÄÏß¡£

 

Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷Í£Ö¹ÔËÐÐʱάÐÞ£ºµ±Ê±É豸³öÏÖC220¹ÊÕÏʱ£¬ÎÒÃÇÊ×ÏÈÓ¦¸Ã´Ó˵Ã÷ÊéÉÏŪÇå³þÆ京Ò壺Motor Feedback Initializing Errorµç»ú·´À¡³õʼ»¯´íÎó

 

Description:¹ÊÕÏ˵Ã÷£º

A number of tests are performed when the motor feedback is initialized.

An error was detected while doing this. This error can be:µ±µç»ú·´À¡³õʼ»¯Ê±£¬»áÖ´ÐÐһЩ²âÊÔ¡£Ö´Ðд˲Ù×÷ʱ¼ì²âµ½´íÎó¡£´Ë´íÎó¿ÉÄÜÊÇ£º

1. Disturbance in the communication with the controller

2. Invalid offset between the high and low dissipating path

3. Error in the micro-controller of the measuring system

1.Óë¿ØÖÆÆ÷ͨПÉÈÅ

2.¸ßºÄɢ·¾¶ºÍµÍºÄɢ·¾¶Ö®¼äµÄÆ«ÒÆÎÞЧ

3.²âÁ¿ÏµÍ³Î¢¿ØÖÆÆ÷´íÎó

 

Cause:Ô­Òò£º

1. Defective motor feedback cable

2. Defective motor feedback

3. Defective measurement system interface

1.µç»ú·´À¡µçÀÂÓÐȱÏÝ

2.µç»ú·´À¡¹ÊÕÏ

3.ȱÏݲâÁ¿ÏµÍ³½Ó¿Ú

 

Remedy:½â¾ö·½·¨£º

1. Check the motor feedback cable

2. Exchange the motor

3. Exchange the measuring system interface (module)

1.¼ì²éµç»ú·´À¡µçÀÂ

2.¸ü»»µç»ú

3.¸ü»»²âÁ¿ÏµÍ³½Ó¿Ú£¨Ä£¿é£©



תÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ
±¾ÎÄÁ´½Ó£ºhttp://m.tlwyjt.net/fuwu/Services_Show12019.htm
ËÅ·þÇý¶¯Æ÷άÐÞ ËÅ·þµç»úάÐÞ  ´¥ÃþÆÁάÐÞ   ±äƵÆ÷άÐÞ


ÁªÏµ·½Ê½£º

µç»°£º021-50157782
ÊÖ»ú£º13817011982 ΢ÐÅͬºÅ
ÓÊÏ䣺shygdzi@163.com
ÁªÏµÈË£ºÕŹ¤
꿅᣼http://m.tlwyjt.net
¡¾ ÎÒÃÇÈ·±£Ð޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿

ÉÏһƪ£ºÁ¦Ê¿ÀÖTDVËÅ·þÇý¶¯Æ÷C215¹ÊÕÏάÐÞ±£Ñø
ÏÂһƪ£º³£ÖÝINVYÓ¢ÍþÌÚCHE100-011G-2±äƵÆ÷OC±¨¾¯¹ÊÕÏάÐÞ

×îÐÂÏà¹ØÄÚÈÝÍƼö£º