ËÅ·þÇý¶¯Æ÷άÐÞ_ÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾_Ê×Ò³

Hi£¬»¶Ó­·ÃÎÊÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾£¡
Äúµ±Ç°µÄλÖ㺠ÍøÕ¾Ê×Ò³> άÐÞÏîÄ¿> ËÅ·þÇý¶¯Æ÷άÐÞ
άÐÞÏîÄ¿
ËÅ·þÇý¶¯Æ÷άÐÞ

²©Ê¿Á¦Ê¿ÀÖTDM3.2-20-300-W0ËÅ·þÇý¶¯Æ÷C213¹ÊÕÏÐÞÀí

·¢²¼ÕߣºHP    À´Ô´£ºÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾     ·¢²¼Ê±¼ä£º2022-10-13

²©Ê¿Á¦Ê¿ÀÖTDM3.2-20-300-W0ËÅ·þÇý¶¯Æ÷C213¹ÊÕÏÐÞÀí

Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷¹ÊÕÏάÐÞ£ºÊ®Ò»·Å¼ÙÆڼ䣬ÎÒÃǹٷ½ÍøÕ¾³£½Óµ½Ò»Ð©¿Í»§×Éѯ¹ØÓÚÁ¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷άÐ޵ĵ绰£¬´ó²¿·Ö¶¼ÊÇÒòΪËÅ·þÇý¶¯Æ÷³öÏÖ±¨¾¯´úÂë¹ÊÕÏÐèҪάÐÞ£¬ÊÂʵÉÏ£¬ÕâÔÚÎÒÃÇάÐÞÖÐÐÄÒ²ÊǾ­³£¿ÉÒÔ¼ûµ½µÄ¡£ÏÂÃæÉϺ£Ñö¹âµç×Ó¾ÍΪ´ó¼Ò×ܽá·ÖÎöÒ»ÏÂÁ¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷ά¹ÊÕϵÄÔ­Òò¼°Ó¦¶Ô·½·¨¡£

 

¹ãÖÝÁ¦Ê¿ÀÖµç»úËÅ·þÇý¶¯Æ÷άÐÞ£ºÊ×ÏÈÎÒÃÇÀ´¿´Ò»Ï±¨´í´úÂëµÄÒâ˼£¬C213¹ÊÕÏ£ºPosition Data Scaling ErrorλÖÃÊý¾ÝËõ·Å´íÎó

 

Cause:Ô­Òò£º

The display format of the position data can be set with the help of the scaling parameter. The internal drive format of the position data is dependent on the applied feedback and the controller resolution. The factor for the conversion of the position data from the internal drive format into the display format or the reverse conversion is outside of the workable area because either:λÖÃÊý¾ÝµÄÏÔʾ¸ñʽ¿ÉÒÔͨ¹ýËõ·Å²ÎÊýÉèÖá£Î»ÖÃÊý¾ÝµÄÄÚ²¿Çý¶¯¸ñʽȡ¾öÓÚÓ¦Óõķ´À¡ºÍ¿ØÖÆÆ÷·Ö±æÂÊ¡£½«Î»ÖÃÊý¾Ý´ÓÄÚ²¿Çý¶¯¸ñʽת»»ÎªÏÔʾ¸ñʽ»ò·´Ïòת»»µÄϵÊýÔÚ¿ÉÐÐÇøÓòÖ®Í⣬ÒòΪ£º

 

Rotary motor and linear positional scaling are not representable or

the average factor for conversion of the position data from the display format into the internal format (or reverse process) is not representable.

•Ðýתµç»úºÍÏßÐÔλÖÃËõ·ÅÎÞ·¨±íʾ»ò

•Î»ÖÃÊý¾Ý´ÓÏÔʾ¸ñʽת»»ÎªÄÚ²¿¸ñʽ£¨»ò·´Ïò¹ý³Ì£©µÄƽ¾ùϵÊý²»¿É±íʾ¡£

 

Remedy:½â¾ö´ëÊ©£º

Connect the drive with a PC and start DriveTop. In the dialog box Scaling/Mechanical system" select a scaling setting.½«Ó²ÅÌÓëµçÄÔÁ¬½Ó£¬È»ºóÆô¶¯DriveTop¡£ÔÚ¡°Ëõ·Å/»úеϵͳ¡±¶Ô»°¿òÖУ¬Ñ¡ÔñËõ·ÅÉèÖá£

Should another scaling installation other than one from DriveTop be used, then the following parameters must be checked.Èç¹ûʹÓÃDriveTopÒÔÍâµÄÆäËûËõ·Å°²×°£¬Ôò±ØÐë¼ì²éÒÔϲÎÊý¡£

 

S-0-0076, Position Data Scaling Type

S-0-0077, Linear Position Data Scaling Factor

S-0-0078, Linear Position Data Scaling Exponent

S-0-0121, Input Revolutions of Load Gear

S-0-0122, Output Revolutions of Load Gear

S-0-0123, Feed Constant

S-0-0076£¬Î»ÖÃÊý¾ÝËõ·ÅÀàÐÍ

S-0-0077£¬ÏßÐÔλÖÃÊý¾Ý±ÈÀýÒò×Ó

S-0-0078£¬ÏßÐÔλÖÃÊý¾ÝËõ·ÅÖ¸Êý

S-0-0121£¬¸ºÔسÝÂÖµÄÊäÈëתËÙ

S-0-0122£¬¸ºÔسÝÂÖµÄÊä³öתËÙ

S-0-0123£¬½øÁϳ£Êý



תÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ
±¾ÎÄÁ´½Ó£ºhttp://m.tlwyjt.net/fuwu/Services_Show12130.htm
ËÅ·þÇý¶¯Æ÷άÐÞ ËÅ·þµç»úάÐÞ  ´¥ÃþÆÁάÐÞ   ±äƵÆ÷άÐÞ


ÁªÏµ·½Ê½£º

µç»°£º021-50157782
ÊÖ»ú£º13817011982 ΢ÐÅͬºÅ
ÓÊÏ䣺shygdzi@163.com
ÁªÏµÈË£ºÕŹ¤
꿅᣼http://m.tlwyjt.net
¡¾ ÎÒÃÇÈ·±£Ð޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿

ÉÏһƪ£ºË³ÒåABBËÅ·þÇý¶¯Æ÷άÐÞ¼Û¸ñMicroFlex e190±¨¾¯4009άÐÞ
ÏÂһƪ£º³£ÖÝINVYÓ¢ÍþÌÚCHE100-011G-2±äƵÆ÷OC±¨¾¯¹ÊÕÏάÐÞ

×îÐÂÏà¹ØÄÚÈÝÍƼö£º