Âí°°É½Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷άÐÞÖÐÐÄ£º¶ÔÓÚ¸÷Æ·ÅƵÄËÅ·þÇý¶¯Æ÷¡¢ËÅ·þµç»úËüÃǷdz£±¦¹ó£¬ÔÚ´ó¶àÊýÇé¿öÏ£¬ÐèÒª°ë¶¨ÆÚ¸üкÍάÐÞ¡£ ¾ÍËãÊÇÆÕͨµÄÁ¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷Ò²ÐèÒª¶¨ÆÚά»¤²ÅÄÜÕý³£¹¤×÷²¢È·±£²»»á·¢ÉúÍ£»ú¡£µ±È»²úÉú¹ÊÕϵÄʱºò£¬ÈÃÈ˺ÜÍ·ÌÛ¡£
רҵάÐÞÁ¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷¿É²âÊÔ£ºÎ¬ÐÞ¼ì²â£ºÖ®Ç°Ò»¸ö×öÉúÎïÒ½Ò©µÄ¿Í»§£¬ÔçÔçµÄËÍÁËһ̨²©Ê¿Á¦Ê¿ÀÖµÄÇý¶¯Æ÷¹ýÀ´¡£ÒòΪ¹«Ë¾»¹Ã»¿ªÃÅ¿Í»§Ö±½Ó¸ø·ÅÔÚÃÅ¿ÚÁË£¬Ð´Á˸ö×ÖÌõ±¨¾¯C211£¨ÒòΪÀϹ˿ÍÁËÒ²·Ç³£ÐÅÈÎÎÒÃǹ«Ë¾£©¡£C211¹ÊÕϺ¬Ò壺Invalid Feedback Data (-> S-0-0022)ÎÞЧ·´À¡Êý¾Ý£¨->S-0-0022£©
ËùÒÔÒ»ÉÏ°à¾ÍÁ¢¿Ì°²ÅÅÁ˼ì²â£ºDescription:¹ÊÕÏ˵Ã÷£º
Invalid data was found while processing the parameters stored in the
motor feedback.´¦Àí´æ´¢ÔÚµç»ú·´À¡¡£
Causes:ÔÒò£º
1. Motor feedback cable not connected or it is defective
2. Defective motor feedback
3. Drive controller defective
1.µç»ú·´À¡µçÀÂδÁ¬½Ó»òÓÐȱÏÝ
2.µç»ú·´À¡¹ÊÕÏ
3.Çý¶¯¿ØÖÆÆ÷¹ÊÕÏ
Remedy:½â¾ö´ëÊ©£º
1. Check motor feedback cable, connect at both ends
2. Exchange the motor
3. Exchange drive controller
1.¼ì²éµç»ú·´À¡µçÀ£¬Á½¶ËÁ¬½Ó
2.¸ü»»µç»ú
3.¸ü»»Çý¶¯¿ØÖÆÆ÷