ËÅ·þÇý¶¯Æ÷άÐÞ_ÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾_Ê×Ò³

Hi£¬»¶Ó­·ÃÎÊÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾£¡
Äúµ±Ç°µÄλÖ㺠ÍøÕ¾Ê×Ò³> άÐÞÏîÄ¿> ËÅ·þÇý¶¯Æ÷άÐÞ
άÐÞÏîÄ¿
ËÅ·þÇý¶¯Æ÷άÐÞ

×¢ËÜ»úרÓñ¶¸£Çý¶¯Æ÷ax5000±¨¾¯´úÂëάÐÞ

·¢²¼Õߣºzyp    À´Ô´£ºÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾     ·¢²¼Ê±¼ä£º2022-2-22

×¢ËÜ»úרÓñ¶¸£Çý¶¯Æ÷ax5000±¨¾¯´úÂëάÐÞ

±¶¸£ËÅ·þÇý¶¯Æ÷άÐÞ³£¼ûµÄ¹ÊÕÏÓУºÉϵçÎÞÏÔʾ¡¢ÓÐÏÔʾÎÞÊä³ö¡¢¹ýµçÁ÷¡¢¹ýµçѹ¡¢Ç·µçѹ¡¢¹ýÈÈ¡¢¹ýÔØ¡¢¹ýËÙ¡¢È±Ïà¡¢¶¶¶¯¡¢±àÂëÆ÷Òì³£¡¢Ä£¿éË𻵡¢½ÓµØ¹ÊÕÏ¡¢²ÎÊý´íÎóµÈ¡£


×¢ËÜ»úרÓñ¶¸£Çý¶¯Æ÷ax5000±¨¾¯´úÂëάÐÞ


 ED43
Under voltage-DC link
ĸÏßµçѹ¹ýµÍ  ¸ÄÉÆÍⲿÖ÷µç·¹©µç

F152
Initialization  of  the
feedback:  Command
failed
·´À¡µçÀ³õʼ»¯´íÎó£¬Ò»°ãÓɸÉ
ÈÅÒýÆð¡£
¼õÉÙ¸ÉÈÅ£¬¼ì²é·´À¡ÏßÀ¼°½ÓÍ·

F19*
Internal
Communication
ÄÚ²¿Í¨Ñ¶²»Á¼
1¡¢ ¼ì²éÊÇ·ñÓÐÇ¿¸ÉÈÅÔ´
2¡¢ ¼ì²éËÅ·þÄÚ²¿ÊÇ·ñÓлҳ¾,¿ÉÒÔ´µ·ç
´¦Àí.µç¹ñÐèÒªÁ¼ºÃÃÜ·â.

F415
Distributed  clocks:
Process data sync
·Ö²¼Ê½Ê±ÖÓͬ²½ÐźÅÒì³£
1¡¢ ×öºÃ½ÓµØ´ëÊ©¡¢½µµÍ¸ÉÈÅ
2¡¢ Èç¹ûÊÇ CPU ÀûÓÃÂʹý¸ß£¬Çë½µµÍ
CPU ÀûÓÃÂÊ
3¡¢ ¼ì²é EtherCAT µçÀÂÓÐÎÞ½Ó²åËɶ¯
4¡¢ Ôö¼Ó DC Shift time

F2A0
Commutation error
1¡¢ ·´À¡µçÀ»ò¶¯Á¦µçÀÂËð»µ
»òÆÁ±Î²ã½ÓµØ²»Á¼
2¡¢ ÓëµÚÈý·½ËÅ·þÆ¥ÅäµÄ»»Ïò
½ÇУÕý´íÎó
3¡¢ PID ²ÎÊý²»ºÏÊÊ
4¡¢ ËÅ·þÇý¶¯Æ÷¹¦ÂÊƫС
5¡¢ ¼ÓËٶȺ͵çÁ÷·½Ïò²»Ò»ÖÂ
1¡¢ ¸ü»»·´À¡µçÀ»ò¶¯Á¦µçÀ£¬¸ÄÉÆÆÁ
±Î²ã½ÓµØ
2¡¢ ÖØмì²é»»Ïà½Ç
3¡¢ µ÷Õû PID ²ÎÊý
4¡¢ Ìá¸ßËÅ·þ¹¦ÂÊ»ò½µµÍ¼ÓËÙ¶È

5¡¢ ¿ÉÒÔ¿¼ÂÇÐÞ¸Ä P-0-0069 ²ÎÊý

F506
Internal communication
error
ÄÚ²¿Í¨Ñ¶´íÎó
¼ì²é EtherCAT ͨѶ½ÓÍ·ÊÇ·ñËɶ¯£¬¿¹¸É
ÈÅ´ëÊ©ÊÇ·ñµ½Î»

F701
Feedback  "general":
Initialization  -
parameter channel
ÓɸÉÈŵÈÔ­ÒòÒýÆð  ¼õÉÙ¸ÉÈÅ£¬Ò²¿ÉÒÔÐÞ¸Ä P-0-150 ²ÎÊý

F702
Feedback "1": Position
invalid
·´À¡´íÎó
1¡¢ ¼ì²é±àÂëÆ÷ÏßÁ¬½ÓÓÐÎÞËɶ¯£¬±àÂë
Æ÷ÆÁ±Î²ã¡¢µØÏß½ÓµØÊÇ·ñÁ¼ºÃ¡£
2¡¢  ¼ì²é±àÂëÆ÷Ï߸½½üÓÐÎÞ¸ÉÈÅÔ´



תÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ
±¾ÎÄÁ´½Ó£ºhttp://m.tlwyjt.net/fuwu/Services_Show6509.htm
ËÅ·þÇý¶¯Æ÷άÐÞ ËÅ·þµç»úάÐÞ  ´¥ÃþÆÁάÐÞ   ±äƵÆ÷άÐÞ


ÁªÏµ·½Ê½£º

µç»°£º021-50157782
ÊÖ»ú£º13817011982 ΢ÐÅͬºÅ
ÓÊÏ䣺shygdzi@163.com
ÁªÏµÈË£ºÕŹ¤
꿅᣼http://m.tlwyjt.net
¡¾ ÎÒÃÇÈ·±£Ð޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿

ÉÏһƪ£ºÄ¸ñÐÂÒ»´ú±ä½°ËÅ·þÇý¶¯Æ÷άÐÞ
ÏÂһƪ£ºÃ»ÓÐÁË

×îÐÂÏà¹ØÄÚÈÝÍƼö£º