Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷άÐÞ£ºÇ°Á½ÌìÄϾ©Ò»¼Ò×öÉúÎïҽѧµÄ¹¤³§ÁªÏµÎÒÃÇ£¬ËûÃdzµ¼äµÄËÅ·þÇý¶¯Æ÷³öÏÖÁËÎÊÌ⣬¸Õ¿ªÊ¼Æô¶¯ºó»¹ºÃ£¬µ«ÔËÐÐÒ»¶Îʱ¼äºóÏÔʾ±¨¾¯´úÂë²¢ÇÒÓÐÔëÒô£¬ÏÖÔÚÒѾͣ»úÁË£¬Ö÷ÒªÏÔʾF226Undervoltage Error£¬Ò»¶ÎÓ¢ÎÄ×Öĸ¡¢³µ¼äµÄ¹¤ÈËҲûÕûÃ÷°×ɶÇé¿ö¡£
Á¦Ê¿ÀÖËÅ·þÇý¶¯Æ÷µÆÉÁάÐÞ£º¹ÊÕÏ˵Ã÷£º
ÒòΪ¾àÀë²»Ô¶£¬¿Í»§Ñ¡ÔñÁË˳·áÓʼĹýÀ´£¬Äõ½É豸֮ºóÎÒÃÇÉϺ£Ñö¹âµç×ӵŤ³ÌʦµÚһʱ¼ä²éÃ÷Á˹ÊÕÏ˵Ã÷Çé¿ö£¬F226Undervoltage ErrorÇ·µçѹ´íÎó¡£
Description:¹ÊÕÏ˵Ã÷£º
The level of the DC bus voltage will be monitored by the drive controller. If
the DC bus voltage falls below a minimal threshold, the drive independently shuts down according to the set error reaction.Ö±Á÷ĸÏßµçѹˮƽ½«ÓÉÇý¶¯Æ÷¿ØÖÆÆ÷¼à¿Ø¡£Èç¹ûÖ±Á÷ĸÏßµçѹµÍÓÚ×îСãÐÖµ£¬Çý¶¯Æ÷¸ù¾ÝÉèÖõĴíÎó·´Ó¦¶ÀÁ¢¹Ø±Õ¡£
Cause:ÔÒò£º
1. The power source has been interrupted without first switching off the drive enable (RF).µçÔ´ÒÑÖжϣ¬µ«Î´Ê×ÏȹرÕÇý¶¯Æ÷ÆôÓã¨RF£©¡£
2. Disturbance in the power supplyµçÔ´¸ÉÈÅ
Remedy:½â¾ö´ëÊ©£º
1 Check the logic regarding the activation of the drive within the connected control.¼ì²éËùÁ¬½Ó¿ØÖÆ×°ÖÃÄÚÇý¶¯Æ÷¼¤»îµÄÂß¼¡£
2 Check the power supply. The error can be cleared by removing the control enable signal.¼ì²éµçÔ´¡£¿ÉÒÔͨ¹ýɾ³ý¿ØÖÆÆôÓÃÐźÅÀ´Çå³ý´íÎó¡£
Çý¶¯Æ÷³£¼û¹ÊÕÏ£ºÉϵçÎÞÏÔʾ£¬È±Ï࣬¹ýÁ÷£¬Ç·Ñ¹£¬¹ýѹ£¬Ä£¿éË𻵣¬±¨´í¡£ÔÚ»úÆ÷·¢Éú¹ÊÕÏʱ£¬²»Òª×ÔÐвð×°»ò½»¸ø·ÇרҵÈËÊ¿£¬ÒÔÃâÔì³É²»±ØÒªµÄËðʧ¡£×¨Òµ´ÓÊÂËÅ·þÇý¶¯Æ÷£¬µçÔ´µÈϵÁеÄάÐÞ¡£
תÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ
±¾ÎÄÁ´½Ó£ºhttp://m.tlwyjt.net/fuwu/Services_Show12075.htm
ËÅ·þÇý¶¯Æ÷άÐÞ ËÅ·þµç»úάÐÞ ´¥ÃþÆÁάÐÞ ±äƵÆ÷άÐÞ
µç»°£º021-50157782
ÊÖ»ú£º13817011982 ΢ÐÅͬºÅ
ÓÊÏ䣺shygdzi@163.com
ÁªÏµÈË£ºÕŹ¤
꿅᣼http://m.tlwyjt.net
¡¾ ÎÒÃÇÈ·±£Ð޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿
ÏÂһƪ£º³£ÖÝINVYÓ¢ÍþÌÚCHE100-011G-2±äƵÆ÷OC±¨¾¯¹ÊÕÏάÐÞ